H6/p5 fit — Precision interference

ISO 286 hole-basis interference fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H6/p5Interference fit
UpperLowerMaxMin
Hole H6+0.013025.01325.000
Shaft p5+0.031+0.02225.03125.022
Max interference
0.031 mm
Min interference
0.009 mm
Mean
−0.020 mm

Fit diagram (µm · zero line = nominal)

0µmHole H6Shaft p5Interference+13+31+22min −9max −31
Hole tolerance zoneShaft tolerance zoneInterference

About H6/p5

Precision locational press fit, e.g. bushes in instrument housings. See press fit tolerance for interference by size across the p6–u6 family.

At Ø25 mm the hole H6 measures 0 mm to +0.013 mm and the shaft p5 +0.022 mm to +0.031 mm, giving an interference of 0.009 mm to 0.031 mm.

How the limits are calculated

Hole H6: fundamental deviation EI = 0, standard tolerance IT6 = 13 µm for 18–30 mm. Shaft p5: fundamental deviation ei = 22 µm, IT5 = 9 µm. Clearance = hole − shaft, evaluated at both extremes. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.

H6/p5 limits by size range

Size (mm)Hole H6Shaft p5
≤ 3+0.006 / 0+0.010 / +0.006
3 – 6+0.008 / 0+0.017 / +0.012
6 – 10+0.009 / 0+0.021 / +0.015
10 – 18+0.011 / 0+0.026 / +0.018
18 – 30+0.013 / 0+0.031 / +0.022
30 – 50+0.016 / 0+0.037 / +0.026
50 – 80+0.019 / 0+0.045 / +0.032
80 – 120+0.022 / 0+0.052 / +0.037
120 – 180+0.025 / 0+0.061 / +0.043
180 – 250+0.029 / 0+0.070 / +0.050
250 – 315+0.032 / 0+0.079 / +0.056
315 – 400+0.036 / 0+0.087 / +0.062
400 – 500+0.040 / 0+0.095 / +0.068

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size. “—” means ISO 286 doesn't define this class below that size (e.g. t only starts at 24 mm).

Is H6/p5 a clearance fit?

No — H6/p5 is an interference fit per ISO 286 (see types of fits). At Ø25 mm it gives an interference of 0.009 mm to 0.031 mm mm, depending which parts of the tolerance zones are paired.

What is the H6/p5 tolerance at 25 mm?

At a nominal size of Ø25 mm, H6 allows a hole diameter from 25.000 to 25.013 mm, and p5 allows a shaft diameter from 25.022 to 25.031 mm.

Related fits