H7/n6 fit — Locational transition

ISO 286 hole-basis transition fit. Enter a nominal size to get the limits.

Unit

Result

Ø25.000 H7/n6Transition fit
UpperLowerMaxMin
Hole H7+0.021025.02125.000
Shaft n6+0.028+0.01525.02825.015
Max clearance
0.006 mm
Max interference
0.028 mm
Mean
−0.011 mm

Fit diagram (µm · zero line = nominal)

0µmHole H7Shaft n6Clearance+21+28+15max +6min −28
Hole tolerance zoneShaft tolerance zoneClearanceInterference

About H7/n6

Firm fit assembled with a press; parts rarely dismantled, e.g. gear rims on hubs, bushes in housings.

At Ø25 mm the hole H7 measures 0 mm to +0.021 mm and the shaft n6 +0.015 mm to +0.028 mm, giving between 0.028 mm interference and 0.006 mm clearance.

How the limits are calculated

Hole H7: fundamental deviation EI = 0, standard tolerance IT7 = 21 µm for 18–30 mm. Shaft n6: fundamental deviation ei = 15 µm, IT6 = 13 µm. Clearance = hole − shaft, evaluated at both extremes. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.

H7/n6 limits by size range

Size (mm)Hole H7Shaft n6
≤ 3+0.010 / 0+0.010 / +0.004
3 – 6+0.012 / 0+0.016 / +0.008
6 – 10+0.015 / 0+0.019 / +0.010
10 – 18+0.018 / 0+0.023 / +0.012
18 – 30+0.021 / 0+0.028 / +0.015
30 – 50+0.025 / 0+0.033 / +0.017
50 – 80+0.030 / 0+0.039 / +0.020
80 – 120+0.035 / 0+0.045 / +0.023
120 – 180+0.040 / 0+0.052 / +0.027
180 – 250+0.046 / 0+0.060 / +0.031
250 – 315+0.052 / 0+0.066 / +0.034
315 – 400+0.057 / 0+0.073 / +0.037
400 – 500+0.063 / 0+0.080 / +0.040

Deviations in mm at the upper end of each range; negative clearance = interference. Clearance columns are shown on wider screens. Sub-ranges (e.g. 18–24 / 24–30) can differ for r, s, t, u, v, x, y, z — use the calculator for the exact size. “—” means ISO 286 doesn't define this class below that size (e.g. t only starts at 24 mm).

Is H7/n6 a clearance fit?

Not always — H7/n6 is a transition fit per ISO 286 (see types of fits). At Ø25 mm it gives between 0.028 mm mm interference and 0.006 mm mm clearance, depending which parts of the tolerance zones are paired.

What is the H7/n6 tolerance at 25 mm?

At a nominal size of Ø25 mm, H7 allows a hole diameter from 25.000 to 25.021 mm, and n6 allows a shaft diameter from 25.015 to 25.028 mm.