h5 tolerance (shaft, IT5)

Shaft tolerance class h5 per ISO 286-1:2010: fundamental deviation es = 0, grade IT5 (4 µm at ≤ 3 mm to 27 µm at 400–500 mm). For an exact size, open the calculator with h5 selected.

Type
Shaft
Grade
IT5
Tolerance
4 … 27 µm
Fund. deviation
es = 0

h5 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 30−43.0002.996
3 – 60−56.0005.995
6 – 100−610.0009.994
10 – 140−814.00013.992
14 – 180−818.00017.992
18 – 240−924.00023.991
24 – 300−930.00029.991
30 – 400−1140.00039.989
40 – 500−1150.00049.989
50 – 650−1365.00064.987
65 – 800−1380.00079.987
80 – 1000−15100.00099.985
100 – 1200−15120.000119.985
120 – 1400−18140.000139.982
140 – 1600−18160.000159.982
160 – 1800−18180.000179.982
180 – 2000−20200.000199.980
200 – 2250−20225.000224.980
225 – 2500−20250.000249.980
250 – 2800−23280.000279.977
280 – 3150−23315.000314.977
315 – 3550−25355.000354.975
355 – 4000−25400.000399.975
400 – 4500−27450.000449.973
450 – 5000−27500.000499.973

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About h5

h5 denotes a shaft tolerance zone with zero line deviation in the ISO 286 system. It is used in H6/h5 (Precision parts located by the fit alone and assembled by hand, e.g. gauges and instrument components.) and G6/h5 (Shaft-basis equivalent of H6/g5, built around a ground reference shaft rather than a reamed hole: gauge blocks, instrument slides, precision jig components.).

At Ø25 mm h5 is 0 / −0.009 mm, i.e. 24.991 to 25.000 mm.

How the limits are calculated

h5 uses grade IT5 (a standard tolerance of 9 µm at 18–30 mm). Fundamental deviation: es = 0: the tolerance zone sits entirely below the nominal size, and IT5 sets its width. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.