r7 tolerance (shaft, IT7)

Shaft tolerance class r7 per ISO 286-1:2010: fundamental deviation ei +10 … +132, grade IT7 (10 µm at ≤ 3 mm to 63 µm at 400–500 mm). For an exact size, open the calculator with r7 selected.

Type
Shaft
Grade
IT7
Tolerance
10 … 63 µm
Fund. deviation
ei +10 … +132 µm

r7 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3+20+103.0203.010
3 – 6+27+156.0276.015
6 – 10+34+1910.03410.019
10 – 14+41+2314.04114.023
14 – 18+41+2318.04118.023
18 – 24+49+2824.04924.028
24 – 30+49+2830.04930.028
30 – 40+59+3440.05940.034
40 – 50+59+3450.05950.034
50 – 65+71+4165.07165.041
65 – 80+73+4380.07380.043
80 – 100+86+51100.086100.051
100 – 120+89+54120.089120.054
120 – 140+103+63140.103140.063
140 – 160+105+65160.105160.065
160 – 180+108+68180.108180.068
180 – 200+123+77200.123200.077
200 – 225+126+80225.126225.080
225 – 250+130+84250.130250.084
250 – 280+146+94280.146280.094
280 – 315+150+98315.150315.098
315 – 355+165+108355.165355.108
355 – 400+171+114400.171400.114
400 – 450+189+126450.189450.126
450 – 500+195+132500.195500.132

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About r7

r7 denotes a shaft tolerance zone with press deviation in the ISO 286 system.

At Ø25 mm r7 is +0.049 / +0.028 mm, i.e. 25.028 to 25.049 mm.

How the limits are calculated

r7 uses grade IT7 (a standard tolerance of 21 µm at 18–30 mm). Fundamental deviation: ei is tabulated directly by ISO 286-1 Table 2; es = ei + IT7. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.

Related classes