d10 tolerance (shaft, IT10)

Shaft tolerance class d10 per ISO 286-1:2010: fundamental deviation es −20 … −230, grade IT10 (40 µm at ≤ 3 mm to 250 µm at 400–500 mm). For an exact size, open the calculator with d10 selected.

Type
Shaft
Grade
IT10
Tolerance
40 … 250 µm
Fund. deviation
es −20 … −230 µm

d10 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3−20−602.9802.940
3 – 6−30−785.9705.922
6 – 10−40−989.9609.902
10 – 14−50−12013.95013.880
14 – 18−50−12017.95017.880
18 – 24−65−14923.93523.851
24 – 30−65−14929.93529.851
30 – 40−80−18039.92039.820
40 – 50−80−18049.92049.820
50 – 65−100−22064.90064.780
65 – 80−100−22079.90079.780
80 – 100−120−26099.88099.740
100 – 120−120−260119.880119.740
120 – 140−145−305139.855139.695
140 – 160−145−305159.855159.695
160 – 180−145−305179.855179.695
180 – 200−170−355199.830199.645
200 – 225−170−355224.830224.645
225 – 250−170−355249.830249.645
250 – 280−190−400279.810279.600
280 – 315−190−400314.810314.600
315 – 355−210−440354.790354.560
355 – 400−210−440399.790399.560
400 – 450−230−480449.770449.520
450 – 500−230−480499.770499.520

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About d10

d10 denotes a shaft tolerance zone with running clearance deviation in the ISO 286 system.

At Ø25 mm d10 is −0.065 / −0.149 mm, i.e. 24.851 to 24.935 mm.

How the limits are calculated

d10 uses grade IT10 (a standard tolerance of 84 µm at 18–30 mm). Fundamental deviation: es is tabulated directly by ISO 286-1 Table 2; ei = es − IT10. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.