j7 tolerance (shaft, IT7)

Shaft tolerance class j7 per ISO 286-1:2010: fundamental deviation ei −4 … −32, grade IT7 (10 µm at ≤ 3 mm to 63 µm at 400–500 mm). For an exact size, open the calculator with j7 selected.

Type
Shaft
Grade
IT7
Tolerance
10 … 63 µm
Fund. deviation
ei −4 … −32 µm

j7 limits by size range

Size (mm)Upper (µm)Lower (µm)Ø max (mm)Ø min (mm)
≤ 3+6−43.0062.996
3 – 6+8−46.0085.996
6 – 10+10−510.0109.995
10 – 14+12−614.01213.994
14 – 18+12−618.01217.994
18 – 24+13−824.01323.992
24 – 30+13−830.01329.992
30 – 40+15−1040.01539.990
40 – 50+15−1050.01549.990
50 – 65+18−1265.01864.988
65 – 80+18−1280.01879.988
80 – 100+20−15100.02099.985
100 – 120+20−15120.020119.985
120 – 140+22−18140.022139.982
140 – 160+22−18160.022159.982
160 – 180+22−18180.022179.982
180 – 200+25−21200.025199.979
200 – 225+25−21225.025224.979
225 – 250+25−21250.025249.979
250 – 280+26−26280.026279.974
280 – 315+26−26315.026314.974
315 – 355+29−28355.029354.972
355 – 400+29−28400.029399.972
400 – 450+31−32450.031449.968
450 – 500+31−32500.031499.968

Deviations at the upper end of each range (Ø columns use that size); use the calculator for the exact size. — : not defined by ISO 286 for that size. Upper/Lower (mm) and inch columns are shown on wider screens.

About j7

j7 denotes a shaft tolerance zone with transition deviation in the ISO 286 system.

At Ø25 mm j7 is +0.013 / −0.008 mm, i.e. 24.992 to 25.013 mm.

How the limits are calculated

j7 uses grade IT7 (a standard tolerance of 21 µm at 18–30 mm). Fundamental deviation: ei is tabulated directly by ISO 286-1 Table 2; es = ei + IT7. See the fundamental deviation table for every letter. Values per ISO 286-1:2010.